Overview

Construction

The aluminium quadruplex URD conductors consist of four twisted and compressed conductors, made of aluminium alloy 1350-H19; Individually isolated with a uniform layer of reticulated polyethylene (XLPE) black resistant to moisture, heat and weather (sunlight) and subsequently assembled together. The neutral conductor is identified by three longitudinal yellow stripes coextruded along the entire conductor. Its form of packaging is spools in lengths according to customer needs.

Applications

Aluminum quadruplex conductors type URD are twisted classes AA and A and are used for secondary distribution lines of electrical power, can be installed directly buried or in electrical pipelines or pipelines, as specified in the national electrical code. This type of conductor can be used in dry and wet places, its maximum operating temperature is 90 ° c and its operating voltage for all applications is 0.6 kv.


Specifications

• ASTM B230: aluminium wires, alloy 1350-H19 for electrical purposes.


ASTM B231: twisted aluminium conductors type 1350-H19 in concentric layers.


ASTM B786: braided aluminium alloy 1350-H19 with 19 wires, unilay formation to be isolated later.


• UL 854: insulated conductors used as power supply cables.


• ANSI/ ICEA S-81-570: cables for 0.6 kv of robust design for installations directly buried as single conductors or conductor assemblies.


• ANSI/ ICEA S-105-692: cables for 0.6 kv isolated with a single layer of thermostable material used in underground distribution systems.


In addition to all national electrical code requirements.

CONDUCTOR URD - CUADRUPLEX China.png

Parameter

Code

Phase conductor

NEUTRO

iameter APROX. (mm)

PESO
TOTAL
APROX. (kg/km)

Capacidad De Corriente (A)

Calibre (AWG o
kcmil)

Sección
Transversal
(mm²)

No. Hilos

Espesor de
Aislamiento (mm)

Calibre (AWG o
kcmil)

Sección
Transversal
(mm²)

No.
Hilos

Espesor
de
Aislamiento (mm)

Conductor
de fase

Cable
Completo

Directamente
Enterrado

En Ducto

Neutral with yellow lines

TULSA

4

21,15

7

1,52

4

21,15

7

1,52

8,92

19,18

388

120

85

DYKE

2

33,62

7

1,52

4

21,15

7

1,52

10,46

22,49

521

155

115

WITTENGERG

2

33,62

7

1,52

2

33,62

7

1,52

10,46

25,32

566

155

115

NOTRE DAME

1/0

53,49

19

2,03

2

33,62

7

1,52

13,21

31,97

812

200

150

PURDUE

1/0

53,49

19

2,03

1/0

53,49

19

2,03

13,21

31,97

894

200

150

SYRACUSE

2/0

67,43

19

2,03

1

42,4

19

2,03

14,33

34,69

998

225

170

LAFAYETTE

2/0

67,43

19

2,03

2/0

67,43

19

2,03

14,33

34,69

1084

225

170

SWARTHMORE

3/0

85,02

19

2,03

1/0

53,49

19

2,03

15,59

37,74

1222

250

195

DAVIDSON

3/0

85,02

19

2,03

3/0

85,01

19

2,03

15,59

37,74

1332

250

195

Mc PHERSON

4/0

107,2

19

2,03

2

33,62

7

1,52

17,01

41,17

1350

290

225

WAKE FOREST

4/0

107,2

19

2,03

2/0

67,43

19

2,03

17,01

41,17

1480

290

225

EARLHAM

4/0

107,2

19

2,03

4/0

107,2

19

2,03

17,01

41,17

1662

290

225

RUST

250

126,7

37

2,41

3/0

85,01

19

2,03

19,45

47,07

1799

315

250

SLIPPERY ROCK

350

177

37

2,41

4/0

107,2

19

2,03

22,10

53,47

2373

385

305

WOFFORD

500

253,3

37

2,41

350

177

37

2,41

25,47

61,64

3372

465

380


PRODUCTS