+86-18945687276

hualuncableco@gmail.com
LV & MV Aerial Bundle Cable (ABC) Overhead Distribution Lines

LV & MV Aerial Bundle Cable (ABC) Overhead Distribution Lines

VOLTAGE: 0.6/1kV 6.35/11kV 12.7/22kV 19/33kV

CONDUCTOR: Class 2 stranded round aluminium; Class 2 stranded Aluminium

INSULATION: XLPE (Cross-linked Polyethylene)

SCREEN: No; Copper Wires or Copper Tape (Light Duty/Heavy Duty); Copper Wires or Copper Tape

OUTER SHEATH: No; HDPE (High Density Polyethylene)

SUPPORT CONDUCTOR: No; Galvanised Steel Wires



0.00
0.00
  

VOLTAGE: 0.6/1kV 6.35/11kV 12.7/22kV 19/33kV

CONDUCTOR: Class 2 stranded round aluminium; Class 2 stranded Aluminium

INSULATION: XLPE (Cross-linked Polyethylene)

SCREEN: No; Copper Wires or Copper Tape (Light Duty/Heavy Duty); Copper Wires or Copper Tape

OUTER SHEATH: No; HDPE (High Density Polyethylene)

SUPPORT CONDUCTOR: No; Galvanised Steel Wires



Overview

LV ABC (Self Supporting & Supporting Core)

Application

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

lv-abc.jpg

Standard

International Electrotechnical Commission International Standards- TNB Specification(IEC 60502)

Australia New Zealand Standard-AS/NZS 3560-1 standards

French Standard-NFC 33-209

HD 626 S1

British Standard-BS 7870


MV ABC (3.8/6.6kV-19/33kV)LV & MV Aerial Bundle Cable (ABC) Overhead Distribution Lines

Application

Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.

mv-abc.jpg

Standard

International Electrotechnical Commission International Standards-IEC 60502 

Australia New Zealand Standard-AS/NZS 3599-1 standards

Parameter

0.6/1kv IEC 60502&TNB
0.6/1kv AS/NZS 3560.1
0.6/1kv DES/LVC/ABC&IEC 60502
0.6/1kv NFC 33-209
0.6/1kv HD 626 S1
0.6/1kv BS 7870-5
IEC 60502 6.35/11 kV
IEC 60502 19/33 kV
AS/NZS 3599 Part 1 6.35/11 KV Al/XLPE /HDPE Non-Screened
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /CWS/HDPE Screened
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /HDPE Non-Screened
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /CWS/HDPE Screened
Number of cores x nominal cross sectionmin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2kNAmmkg/km
1×16+1x 25 RM6.46115.3160
3×16+1x 25 RM6.46119.0290
3×25+1x 25 RM6.48423.2400
3×35+1x 25 RM6.410425.6500
3×50+1x 35 RM8.912930.0680
3×70+1x 50 RM12.116734.9920
3×95+1x 70 RM18.020940.61270
3×120+1x 70 RM18.024644.11510
3×150+1x 95 RM24.228349.21870
3×185+1×120 RM30.833254.92340
3×25+1×25+1×16 RM6.48423.2470
3×35+1×25+1×16 RM6.410425.6560
3×50+1×35+1×16 RM8.912930.0740
3×70+1×50+1×16 RM12.116734.9980
3×95+1×70+1×16 RM18.020940.61330
3×120+1×70+1×16 RM18.024644.11580
3×150+1×95+1×16 RM24.228349.21940
3×185+1×120+1×16 RM30.833254.92410